Not known Details About Australian Standard 4586
Not known Details About Australian Standard 4586
Blog Article
ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6
When it concerns ensuring security in business, industrial, and domestic areas, slip resistance testing is a critical element. At ATTAR (Advanced Technology Testing & Research), we concentrate on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist companies and property owners reduce threats and comply with safety requirements.
With modern equipment such as the pendulum slip test device and moisture meter for concrete, we supply precise and independent slip testing services across Australia. Our expertise covers ASTM F2170 compliance, R Score evaluations, P Ranking tiles, and more, guaranteeing your floors meet the highest safety criteria.
Why Slip Resistance Testing is Vital
Slips and falls are amongst the leading reasons for workplace and public injuries. Proper slip testing helps determine harmful surface areas before accidents occur. Whether you need wet pendulum test assessments or pendulum test for slip resistance, ATTAR provides exact outcomes to boost security.
Secret Services Used by ATTAR
1. Floor Slip Resistance Testing
- Pendulum slip test (AS 4663).
- R Rating and P Rating tiles assessments.
- Independent slip testing services for compliance.
2. Concrete Moisture Testing
- Slab moisture test using advanced moisture meter for concrete.
- ASTM F2170 compliant assessments.
- Concrete slab moisture testing to prevent floor covering failures.
3. Luminance Contrast Testing
- Ensures exposure for aesthetically impaired people.
- Complies with Australian accessibility requirements.
4. On-Site & Lab Testing
- Slip test maker for precise on-site examinations.
- Wet pendulum test for damp surface area slip resistance.
Comprehending Slip Resistance Rankings: R Ranking vs. P Ranking
When carrying out slip resistance testing, 2 essential categories are used:.
- R Score (Ramp Test - DIN 51130)
Steps slip resistance under lubricated conditions, typically utilized in Europe.
- P Ranking (Pendulum Test - AS 4586)
Assesses dynamic friction utilizing a pendulum test slip resistance machine, widely adopted in Australia.
ATTAR provides independent slip testing to determine whether your floor covering fulfills the needed pendulum score tiles standards.
The Value of Concrete Moisture Testing
Excess moisture in concrete slabs can result in flooring failures, mold growth, and adhesive destruction. Our concrete moisture testing services consist of:.
> ASTM F2170 certified in-situ relative humidity testing.
> Moisture meter for concrete assessments.
> Slab moisture test to ensure optimum conditions for floor installations.
By spotting moisture issues early, we help avoid expensive repairs and guarantee long-lasting flooring efficiency.
Luminance Contrast for Availability Compliance
Correct luminance contrast is vital for aesthetically impaired individuals to navigate spaces securely. ATTAR assesses:.
> Stair edges.
> Door frames.
> Handrails.
> Tactile indicators.
Our evaluations guarantee compliance with Australian Impairment Standards (AS 1428.1).
Why Choose ATTAR for Slip Resistance & Moisture Testing?
> NATA Accredited (where appropriate).
> Advanced Testing Equipment (pendulum slip test, moisture meters).
> Nationwide Service Coverage.
> Fast & Reputable Reporting.
For professional slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.
Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.
Typical Applications of Slip Resistance Testing
1. Commercial & Retail Spaces
Shopping center, dining establishments, and workplaces need safe flooring to prevent customer and staff member injuries. Our pendulum slip test guarantees compliance with safety guidelines.
2. Industrial & Storage Facility Facilities
High-traffic industrial environments require resilient, slip-resistant floor covering. ATTAR's slip testing services help keep work environment safety.
3. Health Care & Aged Care Facilities
Healthcare facilities and nursing homes need to lessen slip risks. Our luminance contrast and slip resistance testing make sure safe mobility for patients and personnel.
4. Public Facilities
Paths, train stations, and federal government structures require independent slip testing to fulfill ease of access and safety requirements.
How ATTAR Performs Slip Resistance Testing
Step 1: Surface Assessment
We assess floor covering products and conditions (dry, damp, or contaminated).
Step 2: Pendulum Slip Test (AS 4663)
Using a slip test device, we determine the vibrant coefficient of friction (DCOF).
Step 3: Wet Pendulum Test
Replicates slippery conditions to assess real-world slip dangers.
Step 4: Reporting & Compliance Accreditation
Detailed reports with R Score or P Score tiles categories.
The Science Behind Pendulum Slip Testing
The pendulum test slip resistance method involves a swinging arm with a rubber slider that mimics a foot's movement. The test measures:.
- Slip Prospective Value (SPV).
- Pendulum score tiles classification (P0 to P5).
Higher scores (P4/P5) suggest better slip resistance.
Moisture Testing for Concrete Floors: Preventing Failures
Moisture-related flooring failures can be expensive. ATTAR's concrete slab moisture testing includes:.
- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete click here spot checks.
- Slab moisture test data analysis.
Conclusion
ATTAR (Advanced Technology Testing & Research) is Australia's trusted company of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With innovative technology like the pendulum slip test and moisture meter for concrete, we provide precise, independent, and compliant testing services.
Ensure your residential or commercial property satisfies safety requirements-- contact ATTAR today:.
44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.
By selecting ATTAR, you purchase independent slip testing services, pendulum test slip resistance accuracy, and long-term floor safety solutions. Let us assist you develop more secure, certified, and moisture-resistant environments. Report this page